经常靠泊小日本的船东和船员朋友应该都晓得:小日本PSCO是及其善于检查演习这个科目的,一旦被搞,就要在当地培训才能关闭演习这个缺陷,费用是相当的高!
根据一线船长的反馈,最近小日子对演习的检查又搞了一个新花样。
具体来讲,PSC登轮后会查看船舶的演习计划和记录,如果连续两次的演习均选用的同一个位置,则首先会被记录一个普通17缺陷。
比如消防演习,按照SOLAS第III章第19条的要求,每个月都要搞一次,如果船1月、2月、3月、4月、5月,甚至于6月7月和8月份的演习模拟失火地点均安排在了机舱,PSC就会开具缺陷:All fire drill carried out same situation (E/R) scenario from Jan to Aug - not properly simulated at various scenario。
这个缺陷的意思是:船舶1月至8月的消防演习模拟失火地点均设置在机舱,不能够模拟船舶失火的各种情况。
这个缺陷的依据是SOLAS第III章第19条的3.5.1(Fire drills should be planned in such a way that due consideration is given to regular practice in the various emergencies that may occur depending on the type of ships and the cargo.),这一条要求消防演习在制定计划的时候,要充分考虑船型和货物类型的因素,演习各种紧急情况下可能发生的场景。
显然,如果一艘船演习的地点均选在机舱,是不满足这一条的要求的,这也成为了PSC理直气壮开缺陷的原因。
这项缺陷开具之后,PSC以此为clear ground,让船员搞一个消防演习,是顺水推舟的事了。
船员搞消防演习的时候,有被PSC发现:消防服不会穿、呼吸器不会带、斧子忘了带,手电筒不亮,安全绳没有搞,探火动作不明显,现场联络不畅,通风机没关,模拟火场出现无关人员等情况,将被开具如下缺陷:Fire drill failed in E/R fires though they had excised same situation scenario from Jan to Aug (e.g. How to use BA, wearing fireman’s outfit).
就这么个很顺畅的套路,船舶就被滞留了。
这个滞留例子也提醒各位驾驶员,即使不干活只做paperwork也要打起十分精神,考虑周详,老编再次提醒各位大佬在制定船舶消防演习计划时,要多选几个模拟场景,以防被干!
当然有的朋友触类旁通的想:弃船演习、操舵演习、进入封闭处所演习,需不需要搞不同的场景?
老编查了下公约,弃船和操舵没得选,进入封闭处所公约文本没要求要考虑不同救助场景,所以可以选择同一个地区演习。
另外,老编对最近各地PSCO开具的演习犯错点,整理如下:
1)消防员不能正确穿戴相关消防员装备;
2)呼吸器发出低压报警时,依然进入火场;
3)防火绳缠绕死节;
4)未携带安全灯,没有携带消防斧;
5)进入火场时,手电没有打开
6)没有携带双向对讲设备;
7)消防演习时,发出救生信号;
8)厨房门在演习时一直处于开启状态;
9)应急消防泵没有启动;
10)没有模拟切断厨房电源;
11)呼吸器面罩漏气严重;
12)皮龙漏水;
13)厨房演习时,无人模拟使用过厨房固定灭火系统;
14)皮龙组部分成员穿拖鞋;
15)服务员在厨房灭火期间,依然进入厨房做饭;
16)不管厨房是电器着火,还是油锅或炉灶着火,全部用水;
17)双向对讲设备不是本质安全类型;
18)没有检查自吸式呼吸器压力;
19)演习期间,四名船员停留在火场;
20)驾驶甲板消防员装备缺少探火绳、消防员手斧、腰带和防爆灯;
21)主甲板右舷消防栓出水管路压力不足;
22)船长未能组织全体船员有序进行灭火行动,演习场面混乱,人员职责不清,探火员穿戴消防员装备不熟练;
为了更真切的感受PSCO的缺陷写法,摘引几个PSCO的保真缺陷描述:
1)Crews are not familiar with the fire drills.(船员不熟悉消防演习,这个PSCO写的比较笼统,不建议这么写缺陷)
2)Fire drill not conducted as actual emergency (fire team operator dressed before starting drill).(船员没有按照实际情况开展演习,消防组在开展演习前船上了消防服)
3)Fire drill on low performance, i.e. no reporting of BA pressure before walking to location, 2nd fire fighter incurred dress BA Set not tight on back and safety belt hanging above the knees.(消防演习不成功,具体表现为:没有报告气瓶压力,消防2队没有背带没有系好,安全带挂在了膝盖上)
4)Fire drill poor, lack of control, lack of safety check on BA equipment.(消防演习失败,没有检查自吸式呼吸装置)
5)One fire man wore the B.A. set with the valve not fully open. 2nd fire man was unable to read the pressure because the gauge was cover by the protective jacket.(消防员穿上呼吸器后,没有打开呼吸气瓶的阀门,压力表由于被保护罩遮挡,无法看到压力值)
6)Fire drill substandard: fire fighters stucked several times on doors, one fire fighter going back to clear fire hose, long time passed before fire fighters arrived on fire scene.(消防演习低标准,消防员被门卡主多次,一名消防员回去整理消防水龙,很久才进入火场)
7)Attending officers failed to demonstrate the use of fire main Engine Room Isolation valve, the location of emergency fire pump's controls.(演习人员,不知道消防隔离阀的作用,不知道应急消防泵的控制位置)
8)Galley fire drill no provision on board to test smoke detector head, manual call point activated. Alarm sounded resulting in incomplete muster and no report to bridge.(模拟船舶厨房失火,船上没有配备烟雾发生装备;手动报警点被激发后,全船没有按时集合,没有向驾驶台报告)
以上,是最近发现的演习缺陷,再次提醒各位高度关注。
老编吹牛、喝酒、聊天,请添加微信(另外老编没在任何平台开网店,注册验船师材料随时更新,各平台均为盗版,请不要相信各种虚假宣传,各个渠道高价宣传出售验船师考试题库的也都是假消息,谨防上当。参考:官宣:2024注册验船师报名即将开始,报名前的注意点都在这里!2024年注册验船师考试即将报考,超详细复习指南就在这一篇!)