点击上方“融医荟”关注我们,获取更多资讯
1. 多模态影像融合
多模态影像融合
图1 MRI结构像与PCA/TOF序列融合
图2 CT序列融合(左)与PET序列融合(右)
2. 手术时间缩短
3. 精度提高
4. 可疑岛叶癫痫电极植入
5. 术后个体评估
可视化评估
联影智融智慧一体化神经外科手术机器人可对患者术后影像进行二维及三维评估。二维评估:术后CT与术前MRI融合,逐条路径逐层翻阅确认电极植入情况。三维评估:将植入电极与三维脑实质融合,立体化观察所有电极与脑内部结构、功能区的关系,从而评估植入目标区域的精准度。
6. 并发症减少
7. 总结
在不增加术中或术后并发症风险的情况下,机器人辅助下SEEG手术不仅显著提高了难治性癫痫切除区的精度,同时还被证明安全、准确、高效。而且机器人具有严格的系统算法可辅助规划正交和斜向轨迹,具有非常大的潜力。
[1]Iida, K., & Otsubo, H. (2017). Stereoelectroencephalography: Indication and efficacy. Neurologia Medico-Chirurgica, 57(8), 375–385.
[2]Desai, A., Jobst, B. C., Thadani, V. M., Bujarski, K. A., Gilbert, K., Darcey, T. M., & Roberts, D. W. (2011). Stereotactic depth electrode investigation of the insula in the evaluation of medically intractable epilepsy. Journal of Neurosurgery, 114(4), 1176–1186.;
[3]Gil Robles, S., Gelisse, P., El Fertit, H., Tancu, C., Duffau, H., Crespel, A., & Coubes, P. (2009). Parasagittal transinsular electrodes for stereo-EEG in temporal and insular lobe epilepsies. Stereotactic and Functional Neurosurgery, 87(6), 368–378;
[4]Salado, A. L., Koessler, L., De Mijolla, G., Schmitt, E., Vignal, J.-P., Civit, T., Tyvaert, L., Jonas, J., Maillard, L. G., & Colnat-Coulbois, S. (2018). SEEG is a safe procedure for a comprehensive anatomic exploration of the insula: A retrospective study of 108 procedures representing 254 transopercular insular electrodes. Operative Neurosurgery, 14(1), 1–8.
[5]Lefranc, M., Capel, C., Pruvot, A. S., Fichten, A., Desenclos, C., Toussaint, P., Le Gars, D., & Peltier, J. (2014). The impact of the reference imaging modality, registration method and intraoperative flat-panel computed tomog
raphy on the accuracy of the ROSA(R) stereotactic robot. Stereotactic and Functional Neurosurgery, 92(4), 242–250.
[6]Vakharia VN, Sparks R, O'Keeffe AG, et al.: Accuracy of intracranial electrode placement for stereoencephalography: a systematic review and meta-analysis. Epilepsia. 2017, 58:921-32.
[7]Zhan R, Zhu Y, Shen Y, Shen J, Tong Y, Yu H, Wen L: Post-operative central nervous system infections after cranial surgery in China: incidence, causative agents, and risk factors in 1,470 patients. Eur J Clin Microbiol Infect Dis. 2014, 33:861-6.
[8]Cheng H, Chen BP, Soleas IM, Ferko NC, Cameron CG, Hinoul P: Prolonged operative duration increases risk of surgical site infections: a systematic review. Surg Infect (Larchmt). 2017, 18:722-35.
[9]Valentini LG, Casali C, Chatenoud L, Chiaffarino F, Uberti-Foppa C, Broggi G: Surgical site infections after elective neurosurgery: a survey of 1747 patients. Neurosurgery. 2008, 62:88-96.
[10]Konrad PE, Neimat JS, Yu H, Kao CC, Remple MS, D'Haese PF, Dawant BM: Customized, miniature rapidprototype stereotactic frames for use in deep brain stimulator surgery: initial clinical methodology and experience from 263 patients from 2002 to 2008. Stereotact Funct Neurosurg. 2011, 89:34-41.
[11]Vasconcellos FN, et al. Robotic-Assisted Stereoelectroencephalography: A Systematic Review and Meta-Analysis of Safety, Outcomes, and Precision in Refractory Epilepsy Patients.Cureus. 2023 Oct 25;15(10):e47675.
[12]Philipp LR, Matias CM, Thalheimer S, Mehta SH, Sharan A, Wu C: Robot-assisted stereotaxy reduces target error: a meta-analysis and meta-regression of 6056 trajectories. Neurosurgery. 2021, 88:222-33.
[13]Cardinale F, Cossu M, Castana L, et al.: Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures. Neurosurgery. 2013, 72:353-66.
[14]Philipp LR, Matias CM, Thalheimer S, Mehta SH, Sharan A, Wu C. Robot-assisted stereotaxy reduces target error: a meta-analysis and meta-regression of 6056 trajectories. Neurosurgery. 2021;88(2):222-233.,
[15]Gomes FC, Larcipretti AL, Nager G, et al.: Robot-assisted vs. manually guided stereoelectroencephalography
for refractory epilepsy: a systematic review and meta-analysis. Neurosurg Rev. 2023, 46:102.
[16]Desai A, Jobst BC, Thadani VM, Bujarski KA, Gilbert K, Darcey TM, et al. Stereotactic depth electrode investigation of the insula in the evaluation of medically intractable epilepsy. J Neurosurg. (2011) 114:1176–86.
[17]Gil Robles S, Gelisse P, El Fertit H, Tancu C, Duffau H, Crespel A, et al. Parasagittal transinsular electrodes for stereo-EEG in temporal and insular lobe epilepsies. Stereo Funct Neurosurg. (2009) 87:368–78.
[18]Salado AL, Koessler L, De Mijolla G, Schmitt E, Vignal J-P, Civit T, et al. sEEG is a safe procedure for a comprehensive anatomic exploration of the insula: a retrospective study of 108 procedures representing 254 transopercular insular
electrodes. Oper Neurosurg. (2018) 14:1–8.
[19]Afif A, Chabardes S, Minotti L, Kahane P, Hoffmann D. Safety and usefulness of insular depth electrodes implanted via an oblique approach in patients with epilepsy. Oper Neurosurg. (2008) 62:471–80.
[20]Mullin JP, Shriver M, Alomar S, Najm I, Bulacio J, Chauvel P, Gonzalez-Martinez J: Is SEEG safe? A systematic review and meta-analysis of stereo-electroencephalography-related complications. Epilepsia. 2016, 57:386-401.
声明:本文引用的信息仅代表第三方原作者的观点,与本公司立场无关,本公司不对引用的信息提供任何明示或默示的保证。如您需引用本文信息或本文引用信息的,请与本公众号或相应著作权人联系授权,并自负法律责任。